Hempel’s HS Gas Pipe Coating 87831 is a two-component epoxy polyamine cured coating. Formulated according to the requirements in AMERICAN PETROLEUM INSTITUTE’S STANDARD RP 5L2.
Recommended use
As a one-coat system for internal coating of gas pipes designed for carrying of dry, treated gas. The coating is designed to reduce the drag resistance in the pipeline by making the pipe walls smoother.
Service temperature
Certificates / Approvals
Flash point
28°C [82°F]
VOC content mixed product
Legislation | Value |
---|---|
EU | 155 g/L [1.29 lb/US gal] |
US (coatings) | 155 g/L [1.29 lb/US gal] |
US (regulatory) | 155 g/L [1.29 lb/US gal] |
China | 155 g/L [1.29 lb/US gal] |
Handling
Handle with care. Before and during use, observe safety labels on packaging and paint containers and follow all local and national safety regulations. Always consult Hempel’s Safety Data Sheet for this product along with the Product Data Sheet.
For professional use only.
Parameter | Value |
---|---|
Product code | 87831 |
Product components | Base 87838, Curing Agent 95830 |
Standard shade / code | Brownish red 50610 * |
Gloss | Glossy |
Volume solids | 82 ± 2% |
Specific gravity | 1.4 kg/L [12 lb/US gal] |
Reference dry film thickness | 80 micron [3.2 mils] |
Aluminium shade / code | Dark brown 67120 ** |
Aluminium volume solids | 81 ± 2% |
Cleanliness
New build
Maintenance and Repair
Roughness
Mixing ratio
Base 87838 : Curing Agent 95830 (4:1 by volume)
Stir well before use.
Cleaner
Hempel’s Thinner 08450
Pot life
Product temperature | Pot life |
---|---|
60°C [140°F] | 9 min |
Application method
Tool | Parameters |
---|---|
Dual feed spray | 150 bar [2200 psi], 0.017–0.027″ |
Low | High | Recommended | |
---|---|---|---|
Dry film thickness | 50 µm [2.0 mils] | 100 µm [4.0 mils] | 80 µm [3.2 mils] |
Wet film thickness | 61 µm [2.4 mils] | 122 µm [4.9 mils] | 98 µm [3.9 mils] |
Theoretical spread rate | 16 m²/L | 8.2 m²/L | 10 m²/L |
Product may be specified in another film thickness than indicated depending on purpose and area of use. This will alter spreading rate, drying and curing time and overcoating interval. Overthickness must be closely controlled and never locally exceed 150 micron [6.0 mils] DFT. On irregular surfaces it is recommended to employ special care in avoiding over application.
Product compatibility
Drying time (for 80 µm DFT)
Surface temperature | Hard dry hours |
---|---|
10°C [50°F] | 10 |
20°C [68°F] | 4½ |
30°C [86°F] | 2 |
40°C [104°F] | 1 |
Drying conditions
Overcoating details
Other remarks
Shelf life
Ambient temperature | Base | Curing Agent |
---|---|---|
25°C [77°F] | 12 m | 36 m |
Storage conditions
Dry film thickness | GWP |
---|---|
1 µm | 7.4 g CO₂e/m² |
1 mil | 0.039 lb CO₂e/ft² |
The footprint includes raw materials, in-bound transport, manufacturing, VOCs during/after application.
Values may vary with shade.
Product Data Sheet – HS Gas Pipe Coating 87831
Issued by Hempel A/S – April 2025
Document Version: 4/4
Source: https://www.hempel.com
Technical Guidelines and Explanatory Notes
Last accessed: 28 May 2025
Reference link: https://www.hempel.com/service-and-support/technical-guidelines
Note: Always consult the latest version of the Product Data Sheet and associated documents directly from Hempel’s official website to ensure accuracy and compliance with the most current recommendations.