Hempel’s HS Gas Pipe Coating 87831 is a two-component epoxy polyamine cured coating. Formulated according to the requirements in AMERICAN PETROLEUM INSTITUTE’S STANDARD RP 5L2.

Category Tag Brand:

PRODUCT DATASHEET


Product characteristics

Recommended use
As a one-coat system for internal coating of gas pipes designed for carrying of dry, treated gas. The coating is designed to reduce the drag resistance in the pipeline by making the pipe walls smoother.

Service temperature

  • Maximum, dry exposure only: 120 °C [248°F].

Certificates / Approvals

  • Tested and assessed according to API RP 5L2
  • Tested and assessed according to ISO 15741
  • Tested and assessed according to DIN EN 10301

Product safety

Flash point
28°C [82°F]

VOC content mixed product

Legislation Value
EU 155 g/L [1.29 lb/US gal]
US (coatings) 155 g/L [1.29 lb/US gal]
US (regulatory) 155 g/L [1.29 lb/US gal]
China 155 g/L [1.29 lb/US gal]

Handling
Handle with care. Before and during use, observe safety labels on packaging and paint containers and follow all local and national safety regulations. Always consult Hempel’s Safety Data Sheet for this product along with the Product Data Sheet.

For professional use only.


Product data

Parameter Value
Product code 87831
Product components Base 87838, Curing Agent 95830
Standard shade / code Brownish red 50610 *
Gloss Glossy
Volume solids 82 ± 2%
Specific gravity 1.4 kg/L [12 lb/US gal]
Reference dry film thickness 80 micron [3.2 mils]
Aluminium shade / code Dark brown 67120 **
Aluminium volume solids 81 ± 2%

Surface preparation

Cleanliness

  • Remove oil, grease, salts, contaminants.
  • High pressure fresh water cleaning.

New build

  • Abrasive blasting to min. Sa 2½ (ISO 8501-1) / SP 10 (SSPC)
  • Remove dust, blast media.

Maintenance and Repair

  • As per Hempel’s Specification.

Roughness

  • Surface profile Fine (S) (ISO 8503-2).

Application

Mixing ratio
Base 87838 : Curing Agent 95830 (4:1 by volume)
Stir well before use.

Cleaner
Hempel’s Thinner 08450

Pot life

Product temperature Pot life
60°C [140°F] 9 min

Application method

Tool Parameters
Dual feed spray 150 bar [2200 psi], 0.017–0.027″

Film thickness

Low High Recommended
Dry film thickness 50 µm [2.0 mils] 100 µm [4.0 mils] 80 µm [3.2 mils]
Wet film thickness 61 µm [2.4 mils] 122 µm [4.9 mils] 98 µm [3.9 mils]
Theoretical spread rate 16 m²/L 8.2 m²/L 10 m²/L

Product may be specified in another film thickness than indicated depending on purpose and area of use. This will alter spreading rate, drying and curing time and overcoating interval. Overthickness must be closely controlled and never locally exceed 150 micron [6.0 mils] DFT. On irregular surfaces it is recommended to employ special care in avoiding over application.


Application conditions

  • Surface must be clean, dry, at least 3°C above dew point
  • Surface temperature >10°C [50°F]
  • Max material temp 60°C [140°F]
  • RH: 30–85% during application and curing

Drying and overcoating

Product compatibility

  • Previous coat: None
  • Subsequent coat: None

Drying time (for 80 µm DFT)

Surface temperature Hard dry hours
10°C [50°F] 10
20°C [68°F]
30°C [86°F] 2
40°C [104°F] 1

Drying conditions

  • Sufficient ventilation is important

Overcoating details

  • If maximum overcoating interval is exceeded, roughen surface
  • Surface must be dry and clean prior to overcoat

Other remarks

  • Epoxy chalks in outdoor exposure, does not affect performance
  • Hempel’s Specification supersedes this PDS if in conflict

Storage

Shelf life

Ambient temperature Base Curing Agent
25°C [77°F] 12 m 36 m

Storage conditions

  • Max 40°C [104°F], protect from sunlight, rain, and snow
  • Store per local legislation

Carbon Footprint

Dry film thickness GWP
1 µm 7.4 g CO₂e/m²
1 mil 0.039 lb CO₂e/ft²

The footprint includes raw materials, in-bound transport, manufacturing, VOCs during/after application.
Values may vary with shade.


References

Product Data Sheet – HS Gas Pipe Coating 87831
Issued by Hempel A/S – April 2025
Document Version: 4/4
Source: https://www.hempel.com

Technical Guidelines and Explanatory Notes
Last accessed: 28 May 2025
Reference link: https://www.hempel.com/service-and-support/technical-guidelines

Note: Always consult the latest version of the Product Data Sheet and associated documents directly from Hempel’s official website to ensure accuracy and compliance with the most current recommendations.