Hempatop Direct 700

Hempatop Direct 700

Description

Hempatop Direct 700 is a very fast curing, two-component, high solids, polyaspartic enamel. The product is suitable for direct-to-metal applications as well as topcoat applications.

Category Tags , Brand:

PRODUCT DATASHEET


Product characteristics

Recommended use

Hempatop Direct 700 is recommended as a low VOC, very fast curing, high-build enamel for protection of structural steel in medium to severely corrosive atmospheric environments.
In mild to medium corrosive environments, Hempatop Direct 700 can be used for one-coat direct-to-metal applications. In severely corrosive atmospheric environments, Hempatop Direct 700 can be applied either on zinc metallized surfaces or in two-coat systems primed with zinc epoxy, such as Hempel’s Avantguard products.

Service temperature:

  • Maximum, dry exposure only: 120°C [248°F].

Certificates / Approvals

  • Third-party verified, product-specific Environmental Product Declaration (Type III EPD, ISO 14025, EN 15804)
  • Meets requirements to ISO 12944 when used as part of a predefined paint system. C3
  • Meets requirements to ISO 12944 when used as part of a predefined paint system. C4
  • Meets requirements to ISO 12944 when used as part of a predefined paint system. C5

Features

  • Very fast curing. High solids. Low VOC. High-build. Applicable as direct-to-metal or topcoat.

Product safety

Flash point 40°C [104°F]

VOC content mixed product

Legislation Value Limit value, phase II (2010)ª
EU 140 g/L [1.17 lb/US gal] 500
US (coatings) 140 g/L [1.17 lb/US gal]
US (regulatory) 140 g/L [1.17 lb/US gal]
China 140 g/L [1.17 lb/US gal]

According to specific legislation, see details in the Explanatory Notes available at Hempel website, hempel.com or at your local Hempel website. ªEU Directive 2004/42/CE.

Handling
Handle with care. Before and during use, observe safety labels on packaging and paint containers and follow all local and national safety regulations. Always consult Hempel’s Safety Data Sheet for this product along with the Product Data Sheet.
For professional use only.


Product data

Product code
55970

Product components
Base 55979
Curing Agent 98990

Standard shade / code*
Light grey 11150 **

Gloss
Semi-gloss

Volume solids
85 ± 2%

Product Data Sheet
Hempatop Direct 700
1/4
Issued by Hempel A/S – May 2025
* Immediately after drying the finish may be glossy. Once fully cured the finish will be semi-gloss.
** Colour stability may be affected by exposure to harsh chemical and/or high temperatures.

Specific gravity
1.7 kg/L [14 lb/US gal]

Reference dry film thickness
200 micron [8.0 mils]


Surface preparation

Cleanliness

  • Remove oil, grease and other contaminants by suitable detergent cleaning.
  • Remove salts, detergents and other contaminants by high pressure fresh water cleaning.

New build:

  • Abrasive blasting to min. Sa 2½ (ISO 8501-1) / SP 10 (SSPC).
  • Remove dust, blast media and loose materials.

Maintenance and Repair

  • According to Hempel’s Specification.

Roughness

  • Surface profile Medium (G) (ISO 8503-2).

Consult Hempel’s separate Surface Preparation Guidelines for more details.


Application

Mixing ratio
Base 55979 : Curing Agent 98990
(4 : 1 by volume)
Stir well before use.

Thinner
Hempel’s Thinner 08710
Hempel’s Thinner 08080

Cleaner
Hempel’s Thinner 08710

Pot life

Product temperature Pot life
20°C [68°F] 30 min

Application method

Tool Application parameters
Dual feed spray Nozzle pressure: 150 bar [2200 psi]
Nozzle orifice: 0.017-0.021″
Airless spray Nozzle pressure: 150 bar [2200 psi]
Nozzle orifice: 0.017-0.021″

Spray data are indicative and subject to adjustment. Pressure is for a material temperature of 20°C [68°F].


Film thickness

Specification range Low High Recommended
Dry film thickness 80 micron 250 micron 200 micron
[3.2 mils] [10 mils] [8.0 mils]
Wet film thickness 94 micron 294 micron 235 micron
[3.8 mils] [12 mils] [9.4 mils]
Theoretical spreading rate 11 m²/L [448 sq ft/US gal] 3.4 m²/L [139 sq ft/US gal] 4.3 m²/L [175 sq ft/US gal]

Product may be specified in another film thickness than indicated depending on purpose and area of use. This will alter spreading rate, drying and curing time and overcoating interval. For best performance, avoid excessive film thickness.


Application conditions

  • To avoid condensation, apply on a clean and dry surface with a temperature that is at least 3°C [5°F] above the dew point.
  • Surface temperature must be above 0°C [32°F] during application and curing.
  • Temperature of product must be above 15°C [59°F] during application.

Product Data Sheet
Hempatop Direct 700
2/4
Issued by Hempel A/S – May 2025


Drying and overcoating

Product compatibility

  • Previous coat: None or according to Hempel’s specification.
  • Subsequent coat: None.

Drying time

Surface temperature Touch dry min Hard dry min
10°C [50°F] 60 120
20°C [68°F] 30 60
30°C [86°F] 15 30

Determined for dry film thickness 200 micron [8.0 mils] at standard conditions, see Hempel’s Explanatory Notes for details.

Overcoating

Hempel’s specification supersedes any guidelines indicated in the overcoating table

Quality name 10°C [50°F] 20°C [68°F] 30°C [86°F]
Atmospheric severe
Hempatop Direct 700
Min 2 h 60 min 30 min
Max 60 d 30 d 15 d

Overcoating times are indicative for products of the same generic chemistry. Consult Hempel’s specification for more information.


Drying conditions

  • To obtain the drying time stated, it is important to maintain sufficient ventilation during application, drying and curing.
  • Condensation on the freshly applied coating should be avoided.

Overcoating details

  • If the maximum overcoating interval is exceeded, roughening of the surface is necessary to ensure intercoat adhesion.
  • The surface must be dry and clean prior to application.

Other remarks

  • Hempel’s Specification supersedes any recommendations given in the Product Data Sheets.

Storage

Shelf life

Ambient temperature Base Curing Agent
25°C [77°F] 12 months 24 months

Shelf life from date of production, when stored in original, unopened containers. Thereafter, the product quality must be re-inspected.
Storage at elevated temperatures may reduce shelf life. For advice, please consult Hempel.

Storage conditions

  • The curing agent is sensitive to moisture. Store in a dry place and keep the can tightly closed until use.

Carbon Footprint

Dry film thickness 1 µm 1 mil
GWP (Global Warming Potential) 6.3 g CO₂e/m² 0.033 lb CO₂e/ft²

The carbon footprint is for 1 square meter / square foot of surface area with a dry film thickness of 1 micron / mil.

The scope includes raw materials, in-bound transport to the Hempel factory, Hempel manufacturing processes, and any Volatile Organic Compounds emitted during and after the application of the product.

It is calculated based on the standard shade defined in this PDS.
Values may vary with shade.

Product Data Sheet
Hempatop Direct 700
3/4
Issued by Hempel A/S – May 2025


References

Product Data Sheet – Hempatop Direct 700
Issued by Hempel A/S – May 2025
Document Version: 4/4
Source: https://www.hempel.com

Technical Guidelines and Explanatory Notes
Last accessed: 28 May 2025
Reference link: https://www.hempel.com/service-and-support/technical-guidelines

Note: Always consult the latest version of the Product Data Sheet and associated documents directly from Hempel’s official website to ensure accuracy and compliance with the most current recommendations.